Products Main Page Contact Page Sales Reps Page Opportunities at MDI Catalog PDF Download

Waveguide Terminations
High Power
High Power Waveguide Termination
MDI's line of high power waveguide terminations offers superior power handling capability and excellent performance at a reasonable price.

Contact us if you have specific requirements not covered by the listed models.


Find Coaxial Terminations Here



 Waveguide Terminations, High Power
Model Frequency Range
(GHz)
Waveguide Size Flange Average Power
(Watts)
VSWR* Length
Inches
(centimeters)
6WH430 1.70 - 2.60 WR430 UG437B/U 5000 1.10:1 36.0 (91.4)
6WH340 2.20 - 3.30 WR340 UG437B/U-? 5000 1.10:1 36.0 (91.4)
6WH284 2.65 - 3.95 WR284 UG584/U 5000 1.10:1 34.0 (86.4)
6WH229 3.30 - 4.90 WR229 CMR229 5000 1.10:1 30.0 (76.2)
6WH187 3.95 - 5.85 WR187 UG407/U 3000 1.10:1 24.0 (61.0)
6WH159 4.90 - 7.05 WR159 CMR159 3000 1.10:1 24.0 (61.0)
6WH137 5.85 - 8.20 WR137 UG441/U 2000 1.10:1 20.0 (50.8)
6WH112 7.05 - 10.00 WR112 UG138/U 1000 1.10:1 14.0 (35.6)
6WH90 8.20 - 12.40 WR90 UG135/U 1500 1.15:1 9.8 (24.9)
6WH75 10.00 - 15.00 WR75 M3922/53-008 800 1.10:1 10.0 (25.4)
6WH62 12.40 - 18.00 WR62 UG1665/U 500 1.10:1 10.0 (25.4)
6WH42 18.00 - 26.50 WR42 UG595/U 250 1.10:1 8.0 (20.3)
6WH28 26.50 - 40.00 WR28 UG599/U 200 1.10:1 6.0 (15.2)
  * VSWR is typical over the entire band.
   Improved VSWR available over narrower bandwidths.

For higher power ratings, see: Maximum Power Ratings Table


Back to Waveguide Products Page





For Sales Assistance, Contact: sales@mwdevices.com

For Product Information, Contact: info@mwdevices.com

For Engineering Support, Contact: engineering@mwdevices.com